2296_Elioth_Majunga_8 1 / 3
2296_Elioth_Majunga_7 2 / 3
2296_Elioth_Majunga_3 3 / 3

2296_Elioth_Majunga_8

Majunga tower

Elioth has been part of the Majunga project from the Preliminary Design stage to manage the environmental issues and prepare for the GREENBUILDING and BREEAM certifications (level Excellent aimed at).

Among the studies carried out, the CFD and thermal-dynamic simulations helped not only to understand but to validate a natural ventilation strategy. Particular attention was also paid to the wall surfaces (double skin/simple skin, double/triple glazing) depending on the building’s orientation, taking into account the life cycle of CO2 emissions and the financial aspects.

  • Type: _ee
  • State: Etudes
  • Year: 2009
  • City: La Défense, Paris
  • Client: Unibail-Rodamco (via JPV)
  • Area: 69500 m²
  • Team: Agence Jean Paul Viguier + INEX + EPPAG + SETEC
  • Delivery: Etudes environnementales HQE et BREEAM